X Series E53 X5 4.4i (M62) OFFRD
12 14 522
Replacing pulse generator on left inlet
camshaft (M62)
Interrogate fault memory of DME control unit.
Switch off ignition.
Turn fasteners on acoustic cover 90
°
counterclockwise.
Remove acoustic cover.
Disconnect plug connection (1) on left cable strip.
Unclip cable from cable holder (2).
Release screw (3).
Remove pulse generator (4).
Installation:
Coat sealing ring with anti-friction rubber coating (e.g.
petroleum jelly).
Note:
Interrogate fault memory of DME control unit.
Check stored fault messages.
Rectify faults.
Now clear the fault memory.
RA Replacing pulse generator on left inlet camshaft (M62)
BMW AG - TIS
08.02.2013 02:35
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -