bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Replacing Pulse Generator On Right Inlet Camshaft (M62) > < 1 RA Replacing Pulse Generator (M62)|Page 697
Page 1
background image

12 14 522

Replacing pulse generator on left inlet
camshaft (M62)

Interrogate fault memory of DME control unit.

Switch off ignition.

Turn fasteners on acoustic cover 90

°

 counterclockwise.

Remove acoustic cover.

Disconnect plug connection (1) on left cable strip.

Unclip cable from cable holder (2).

Release screw (3).

Remove pulse generator (4).

Installation:

Coat sealing ring with anti-friction rubber coating (e.g.
petroleum jelly).

Note:

Interrogate fault memory of DME control unit.

Check stored fault messages.

Rectify faults.

Now clear the fault memory.

RA  Replacing pulse generator on left inlet camshaft (M62)

BMW AG - TIS

08.02.2013  02:35

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

3 RA Replacing Pulse Generator On Right Inlet Camshaft (M62) > < 1 RA Replacing Pulse Generator (M62)|Page 697