X Series E70 X5 3.0Si (N52K) OFFRD
Installation:
Seal (1) must always be replaced.
Important!
Grounding cable (1) must be replaced if it has been
detached once!
Disconnect grounding cable (1) towards top.
Carefully raise service cover.
Unclip plastic tube (1).
Unlock and disconnect quick-connect coupling (2).
Important!
Catch escaping fuel in suitable container.
No fuel is permitted to get into the interior!
Remove fuel pump.
With fuel pump removed, disconnect plug connection (1) in tank
and replace grounding cable (2).
RA Removing and installing or replacing fuel gauge sensor (petrol/gasoline, right)
BMW AG - TIS
06.02.2013 11:10
Issue status (12/2007) Valid only until next DVD is issued
Copyright