Installation:

Threads of new oxygen sensors are already coated with
Never Seez Compound.

If the oxygen sensor is reused, only apply a thin and uniform coat
of Never Seez Compound (refer to BMW Parts Service) to
thread.

Oxygen sensor section projecting into exhaust system branch
must not be cleaned or come into contact with lubricant.

Installation:

Tighten down monitor sensor (2) with special tool 

11 7 030 .

Tightening torque 11 78 1AZ

Pay attention to cable routing of monitor sensor.

Installation:

Read out fault memory of control unit of Digital Motor Electronics
(DME).

Check stored fault messages.

Rectify faults.

Now clear the fault memory.