X Series E70 X5 4.8i (N62TU) OFFRD
34 00 050
Bleeding brake system with DSC
Necessary preliminary tasks:
•
Remove left microfilter housing cover
•
Read and comply with General Information.
Important!
When replacing or repairing, observe the filling and bleeding
instructions for the following parts:
-
Tandem brake master cylinder
-
Hydraulic unit
-
Components and connecting lines which are fitted
between these assemblies.
Connect bleeder unit with max. 2 bar filling pressure.
A second person is needed to help carry out this work.
Connect DIS.
Select path: Service functions - Chassis/Suspension - Slip control
systems - Bleeding procedure.
Important!
Check relevant Operating Instructions for each device.
Charging pressure should not exceed 2 bar.
Connect brake fluid changer to expansion tank and switch on.
Flushing brake system completely
Connect bleeder hose with collecting tray to bleeder valve on rear
right brake caliper.
Open bleeder valve and purge until clear, bubble-free brake fluid
emerges.
Close bleed valve.
Follow same procedure on rear left, front right and front left wheel
brake.
RA Bleeding brake system with DSC
BMW AG - TIS
08.02.2013 04:51
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -