X Series E70 X5 4.8i (N62TU) OFFRD
61 12 002
Replacing battery positive lead (from battery
to luggage compartment connector)
Warning!
Observe safety instructions for handling vehicle battery.
Notes and instructions on Intelligent Battery Sensor IBS.
Important!
Do not under any circumstances pull/lever safety battery
terminal off by force.
Necessary preliminary tasks:
•
Remove flap in luggage compartment panel on right
•
Disconnect negative battery cable
Disconnect plug connection (1) on safety battery terminal (2).
Open cover and release nut (3).
Tightening torque 61 21 2AZ
.
Open cover (2) and slacken nut underneath.
Tightening torque 61 21 1AZ
.
Using a screwdriver, expand locking bracket (6) at lower end and
clip out.
Raise distribution box slightly and remove safety battery terminal.
Open cover (1).
Slacken nut (2).
Tightening torque 61 12 3AZ
.
Disconnect battery positive lead.
RA Replacing battery positive lead (from battery to luggage compartment connector)
BMW AG - TIS
08.02.2013 12:31
Issue status (12/2007) Valid only until next DVD is issued
Copyright