X Series E83 X3 3.0Sd (M57T2) OFFRD
Check testing equipment for leaks!
Select "Measurement/ Pressure" function on Diagnosis and
Information System (DIS).
Increase pressure by 0.2 bar with pressure regulator on special
tool 16 1 171 .
Using special tool 13 3 010 , disconnect supply line from special
tool 16 1 171 .
Read off and note down pressure.
Wait 60 secs.
Read off pressure again and compare with starting pressure
value.
Measurement evaluation:
Pressure drop > 0.012 bar
Testing equipment leaking.
Check connection points for
leaks.
Check filler cap pressure relief!
Select "Measurement/ Pressure" function on Diagnosis and
Information System (DIS).
Increase pressure by 0.3 bar with pressure regulator on special
tool 16 1 171 .
Using special tool 13 3 010 , disconnect supply line from special
tool 16 1 171 .
Read off and note down pressure.
Wait 60 secs.
Read off pressure value again and compare with starting pressure
value.
Measurement evaluation:
Pressure drop > 0.012 bar
Filler cap pressure relief
valve faulty.
Replace fuel tank cap.
RA Checking filler cap pressure relief valve
BMW AG - TIS
19.02.2013 19:12
Issue status (12/2007) Valid only until next DVD is issued
Copyright