bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Replacing Oxygen Monitor Sensor (cylinders 4-6) > < 2 RA Replacing Oxygen Monitor Sensor (cylinders 1-3)
Page 2
background image

Release oxygen monitor sensor from above with special tool 
11 7 020 .

Installation:

The threads of new oxygen monitor sensors are already
coated with Never Seez compound.

If an oxygen monitor sensor is reused, only apply a thin and
uniform coat of Never Seez compound (refer
to BMW Parts Service) to thread.

Oxygen monitor sensor section projecting into exhaust system
branch must not be cleaned or come into contact with
lubricant.

Cover oxygen monitor sensor when applying underseal. 

Tightening torque  11 78 1AZ

.

Installation:

Check stored fault messages.

Now clear the fault memory.

RA  Replacing oxygen monitor sensor (cylinders 1-3)

BMW AG - TIS

15.02.2013  12:04

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

3 RA Replacing Oxygen Monitor Sensor (cylinders 4-6) > < 2 RA Replacing Oxygen Monitor Sensor (cylinders 1-3)