Century V6-3100 3.1L VIN M SFI (1998)
Service Port HVAC: Service and Repair
Tool Required:
J 39037 Octagon Socket
Remove or Disconnect
1. Cap.
2. Recover refrigerant.
3. Service valve.
Install or Connect
1. Service valve.
Tighten
^
Valve to 11 N.m (98 lb. in.).
2. Evacuate, recharge, and leak test system.
3. Cap.
Tighten
^
Cap 1/4 to 1/2 turn after seal washer contacts access fitting.