Cornering Lamp: Initial Inspection and Diagnostic Overview

Voltage is applied when the ignition is in the RUN. BULB TEST or START position through the TURN SIGNAL Fuse in the fuse block, to the turn
signal switch through circuit 539. When the turn signal switch is placed in the TURN LEFT position, voltage is applied through the closed contacts of
the turn signal switch, to the LEFT cornering lamps through circuit 57. The LH cornering lamps are grounded through circuit 1350 to G101. When the
turn signal switch is placed in the TURN RIGHT position, voltage is applied through the closed contacts of the turn signal switch. to the RH cornering
lamps through circuit 58. The RH cornering lamps are grounded through circuit 1250 to G102.