buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Customer Interest:|8582|Page 5669 > < Aspirator, HVAC|Description and Operation
Page 1
background image

Blower Motor: Customer Interest
A/C - Blower Deep Roar After Start Up In Cold Weather

Bulletin 85--8-2

Date May '84

Ref. No. 84-210-8
SUBJECT:

HEATER BLOWER DEEP ROAR AFTER START UP IN COLD WEATHER

MODELS AFFECTED:

1985 ELECTRA WITH C68, ELECTRONIC TOUCH CLIMATE CONTROL

ILLUSTRATION 1

A condition has been noted an some early 1985 Electras with C68 where a deep roar can be heard several minutes after start up in cold weather. If a car
with this condition is encountered, it can be improved by applying a bead of Dow Corning 111 Compound (or equivalent heavy consistency silicone
lubricant) around the temperature door opening. See illustration 1 for area of application. Access to the temperature door opening can be gained by
removing the heater outlet. The bead of silicone must be applied to the HVAC Module (Not to the temperature door itself) but must contact the vinyl seal
around the entire perimeter of the door when the door is closed.

Dow Coming 111 Compound is available in a 5.3 oz. tube. For information on availability in your area contact Dow Corning on the toll free phone
number 800-447-4700.
WARRANTY INFORMATION

Labor Operation Number

T5068

Failure Code

92

Labor Hours

.4

Parts Allowance

2.06