background image

Variable Valve Timing Actuator: Service and Repair
Camshaft Position Actuator Replacement - Bank 2 (Left Side) Exhaust

CAMSHAFT POSITION ACTUATOR REPLACEMENT - BANK 2 (LEFT SIDE) EXHAUST

Special Tools: EN-48313 Timing Chain Retention Tool

Removal Procedure

1. Remove the lower intake manifold. See: Intake Manifold/Service and Repair

2. Remove the left camshaft cover. See: Cylinder Head Assembly/Valve Cover/Service and Repair

3. Remove the left intake and exhaust camshaft position sensors. See: Powertrain Management/Computers and Control Systems/Camshaft Position

Sensor/Service and Repair

4. Remove the left intake and exhaust camshaft position actuator solenoid. See: Variable Valve Timing Solenoid/Service and Repair

Important: Rotate the crankshaft balancer bolt in a clockwise direction ONLY.

5. Rotate the crankshaft balancer using the balancer bolt until the camshafts are in a neutral (low tension) position. The camshafts will be parallel

with the camshaft cover rail (1).