buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Relays and Modules - Lighting and Horns > < HVAC - Manual|Page 411
Page 1
background image

Control Module HVAC: Service and Repair

Blower Motor Control Module Replacement

Removal Procedure

1. Remove the right side instrument panel (I/P) insulator.

2. Disconnect the electrical connector from the blower control module.
3. Remove the 2 heat stakes from the blower control module using a small chisel.
4. Remove the blower control module.

Installation Procedure

1. Install the blower control module.

Notice:  Refer to Fastener Notice.

2. Install the 2 new screws in the pre-drilled holes to the side of the heat stakes in the blower control module and the HVAC module assembly.

Tighten the screws to 1.5 N.m (13 lb in).

3. Connect the electrical connector to the blower control module.
4. Install the right side I/P insulator.
5. Refer to Programming and Relearning for programming and setup information. See: Testing and Inspection/Programming and Relearning

Relays and Modules - Lighting and Horns > < HVAC - Manual|Page 411