Fuel Line Coupler: Service and Repair
Quick Connect Fitting(s) Service (Plastic Collar)

QUICK CONNECT FITTING(S) SERVICE (PLASTIC COLLAR)

REMOVAL PROCEDURE

1. Relieve the fuel system pressure. Refer to Fuel Pressure Relief Procedure.

CAUTION:  Refer to Gasoline/Gasoline Vapors Caution in Service Precautions.

2. Blow dirt out of the fitting using compressed air.

CAUTION:  Wear safety glasses when using compressed air, as flying dirt particles may cause eye injury.

3. Squeeze the plastic tabs of the male end connector.

4. Pull the connection apart.
5. Using a clean shop towel, wipe off the male pipe end
6. Inspect both ends of the fitting for dirt and burrs.
7. Clean or replace the components as required.

INSTALLATION PROCEDURE

1. Apply a few drops of clean engine oil to the male pipe end.