background image

Variable Valve Timing Actuator: Service and Repair

Camshaft Position Actuator Magnet Replacement

Removal Procedure

1. Remove the intake manifold cover. Refer to Intake Manifold Cover Replacement   (See: Intake Manifold/Service and Repair).
2. Disconnect the camshaft position actuator magnet electrical connector (2).

3. Remove the camshaft position actuator magnet bolts.
4. Remove the camshaft position actuator magnet and O-ring seal.

Installation Procedure