Refrigerant Pressure Sensor / Switch: Description and Operation
Pressure Cycling Switch

A/C System Switch Locations

DESCRIPTION   

The refrigeration cycle (on and off operation of the compressor) is controlled by a switch which senses the low-side pressure as an indicator of
evaporator temperature. The pressure cycling switch is the freeze protection device in the system and senses refrigerant pressure on the suction side of
the system. This switch is located on the accumulator on a standard Schrader-type valve low-side fitting.

OPERATION   

Additional compressor protection results from the operating characteristics of the low-side pressure cycling system. If a massive discharge occurs in
the low side of the system or the orifice tube becomes plugged, low-side pressures could be insufficient to close the contacts of the pressure switch. In
the event of a low charge, insufficient cooling accompanied by rapid compressor clutch cycling will be noticed at high air temperatures.