buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Inducing Intermittent Fault Conditions|Page 14 > < Inducing Intermittent Fault Conditions
Page 1
background image

Accessory Delay Module: Diagnostic Aids
Measuring Frequency

MEASURING FREQUENCY

NOTE:  Refer to Test Probe Notice in Service Precautions.

The following procedure determines the frequency of a signal.

IMPORTANT:  Connecting the DMM to the circuit before pressing the Hz button will allow the DMM to autorange to an appropriate range.

1. Apply power to the circuit.
2. Set the rotary dial of the DMM to the V (AC) position.
3. Connect the positive lead of the DMM to the circuit to be tested.
4. Connect the negative lead of the DMM to a good ground.
5. Press the Hz button on the DMM.
6. The DMM will display the frequency measured.

Inducing Intermittent Fault Conditions|Page 14 > < Inducing Intermittent Fault Conditions