buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Relays and Modules - Instrument Panel > < Blower Control Module (RPO C68, CJ2)
Page 1
background image

Control Module HVAC: Service and Repair
Automatic Control A/C Programmer (RPO C68, CJ2)

PROGRAMMER (RPO C68 or CJ2)

Programmer Assembly And Temperature Valve Link

REMOVE OR DISCONNECT    

^

Disable Supplemental Inflatable Restraint (SIR) system, Refer to Air Bags and Seat Belts / Air Bags (Supplemental Restraint Systems). See:
Restraint Systems/Air Bag Systems 

1. Instrument Panel (I/P) Compartment (Glove Compartment) disengage stops and swing down.
3. Electrical and vacuum connectors.
2. Driver temperature valve link rod.
4. Screws and programmer from vehicle.

INSTALL OR CONNECT   

1. Screws after positioning programmer.

^

Tighten screws to 1.4 Nm (12 lb. in.).

2. Electrical and vacuum connectors.
3. Driver temperature valve link rod.
4. Adjust Driver temperature Valve Link Rod, refer to Temperature Valve Link Adjustment. 

 .

5. I/P compartment insert by pushing forward.
^

Enable SIR system, Refer to Air Bags and Seat Belts. See: Restraint Systems/Air Bag Systems

TEMPERATURE VALVE LINK ADJUSTMENT

1. Pull valve link from retainer on programmer output crank (if not left disassembled). 
2. Start car; set fan to HI and temperature to 33°C (90°F). If ambient temperature is above 33°C (90°F), disconnect in-vehicle temperature sensor.
3. Allow 45 seconds minimum for programmer motor to move output crank to its full hot position. Then move temperature valve to full hot position;

snap valve link into retainer on output crank.