Rainier 2WD V8-5.3L VIN P (2004)
Air Door Actuator / Motor: Service and Repair
Recirculation Actuator Replacement
RECIRCULATION ACTUATOR REPLACEMENT
REMOVAL PROCEDURE
1. Remove the HVAC module assembly.
2. Remove the air inlet assembly screws.
3. Remove the air inlet assembly.
4. Remove the recirculation actuator screws.
5. Remove the electrical connector from the recirculation actuator.
6. Remove the recirculation actuator.
INSTALLATION PROCEDURE
1. Install the recirculation actuator.
2. Install the screws to the recirculation actuator.
NOTE: Refer to Fastener Notice in Service Precautions.
See: Service Precautions/Vehicle Damage Warnings
Tighten
Tighten the screws to 1.9 N.m (17 lb ft).
3. Install the air inlet assembly.
4. Install the air inlet assembly screws.
Tighten
Tighten the screws to 1.9 N.m (17 lb ft).
5. Connect the electrical connector to the recirculation actuator.
6. Install the HVAC module assembly.