Rainier 2WD V8-5.3L VIN P (2004)
module-left deployment harness.
26. Strip 13 mm (0.5 in) of insulation from both ends of these wires.
27. Twist together one end from each of the wires in order to short the wires. Deployment wires shall remain shorted, and not connected to a power
source until you are ready to deploy the inflator module.
28. Twist together one connector wire lead to one deployment wire.
29. Inspect that the previous connection is secure.
30. Bend flat the twisted connection.
31. Secure and insulate the connection using electrical tape.
32. Twist together, bend, and tape the remaining connector wire lead to the remaining deployment wire.