Regal L4-2.0L Turbo (2011)
Oil Level Sensor For ECM: Diagnostic Aids
Yazaki Connectors (16-Way)
Yazaki Connectors (16-Way)
Special Tools
*
EL-38125-580 - Terminal Release Tool Kit
*
J-38125-215 - Terminal Release Tool
For equivalent regional tools, refer to Special Tools (See: Power and Ground Distribution/Tools and Equipment).
Terminal Removal Procedure
1. While depressing the lock, pull the two connector halves apart.
Note: The terminal position assurance (TPA) is fragile and may break if not done carefully.
2. Use a small flat-blade tool to very carefully push the TPA towards the face of the connector on both sides of the connector.