buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Chart C-12A Coolant Fan Control Circuit|Page 2249 > < Chart C-12A Coolant Fan Control Circuit|Page 2247
Page 2
background image

Chart C-12C-A Wiring Diagram

CIRCUIT DESCRIPTION:

The ECM and three relays are used to control the two cooling fans.

Low Speed Fan Operation - Low speed operation of both fans is controlled by the ECM.  The ECM energizes the fan relay "B" (in the right hand power
center) for low speed fans when coolant temperature exceeds 101~C (214~F) or A/C requested. With ignition "OFF" the ECM will operate the cooling
fans at low speed if coolant temperature exceeds 110~C (230~F) and manifold air temperature exceeds 39~C (102~F) at time of key "OFF".  The ECM
will keep the low speed fans "ON" with the key "OFF" for up to 2 minutes or until or until coolant temperature falls below 99~C (210~F).

High Speed Fan Operation - High speed fan operation of both fans is controlled by the ECM.  The ECM energizes all three cooling fan relays when
coolant temperature exceeds 108~C (226~F) or A/C refrigerant pressure is sufficient to close the A/C head pressure switch (refrigerant pressure over
1380 kPa, 200 psi). High speed fans should not run with the ignition "OFF."

TEST DESCRIPTION:

Numbers below refer to circled numbers on the diagnostic chart.

1.

Checks for B+ at relay harness connector.

2.

Test light "ON" verifies circuit 536 to cooling fan relay. 

3.

Jumpering terminals "1" to "4" in relay areas "C" bypasses the relay and should cause the fan to run, if the fan motor and wiring are operational.

4.

This checks for B+ and ground to the fan motor. A test light "ON" at this point indicates a faulty fan motor connection or motor.

 