Regal V6-231 3.8L VIN L SFI (1990)
Evaporator Core: Customer Interest
Installation of Afterblow Module
THE FOLLOWING STEPS ARE THE INSTRUCTIONS FOR THE INSTALLATION OF THE AFTERBLOW MODULE.
IMPORTANT
The afterblow module will enable the blower to run at high speed for five
(5) minutes approximately fifty (50) minutes after the vehicle ignition is turned off, if the compressor was engaged for four (4) minutes or more during
the last ignition cycle.
IMPORTANT:
All the connections of the afterblow module harness to the vehicle wiring should be spliced, using the proper techniques shown in section 8A of
the appropriate Service Manual. The splices should be made using splice clips, solder and wrapping the splice with electrical tape. Do not use the
instant connectors such as 3M's "SCOTCHLOK" brand.
FIGURE 3 - CIRCUIT DIAGRAM
IMPORTANT:
The circuit diagram, shown in Figure 3, shows the circuit numbers generally used on the subject model year vehicles. However, to make sure of
the correct circuits and wire colors are spliced into, refer to section 8A of the Service Manual.