Regal V6-252 4.1L (1984)
Blower Motor: All Technical Service Bulletins
A/C - Blower Motor Inoperative or Will Not Stop Running
Bulletin 88-1-23A
Date Dec., '89
Ref. No. 89-139A-1
Corp. Ref. No. 831217R
SUBJECT:
BLOWER MOTOR INOPERATIVE OR WILL NOT STOP RUNNING (NEW PARTS KIT)
MODELS AFFECTED:
1982-88 LESABRE AND ELECTRA ESTATE WAGON 1982-85 LESABRE 1982-84 ELECTRA AND PARK AVENUE
1982-87 REGALS 1982-85 RIVIERAS WITH C68 A/C
NOTICE:
This bulletin has been revised to add the Regals and Rivieras and to correct the parts statement.
Some 1982-88 Buicks with C68 HVAC systems may exhibit the subject condition due to a shorted power transistor in the power module of the automatic
HVAC system.
This condition may be addressed by the installation of a power module service kit, part number 10135631.
Parts are currently available from GMSPO.
Labor Operation Number:
T1397
Labor Time:
.5 Hours