Regal V6-3.8L VIN K (1997)
Vacuum Pump HVAC: Service and Repair
Remove or Disconnect
1. Right side instrument panel insulator.
2. Vacuum lines and electrical connections from vacuum electric solenoid.
3. Vacuum electric solenoid mounting screws.
4. Vacuum electric solenoid.
Install or Connect
1. Vacuum electric solenoid.
2. Vacuum electric solenoid mounting screws.
Tighten
^
Screws to 1.5 N.m (13 lb. in.).
3. Vacuum lines and electrical connections to vacuum electric solenoid.
4. Right side instrument panel insulator.