Regal V6-3100 3.1L VIN M SFI (1996)
Backup Lamp: Initial Inspection and Diagnostic Overview
Troubleshooting Hints
1. Check R/CMPT REL Fuse by visual inspection.
2. Check the Backup Lamps for damage to the filament or corrosion between the bulb and the lamp socket.
^
Check for a broken (or partially broken) wire inside of the insulation which could cause system malfunction but prove "GOOD" in a
continuity/voltage check with the system disconnected. These circuits may be intermittent or resistive when loaded, and if possible, should be
checked by monitoring for a voltage drop with the system operational (under load).
^
Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems (refer ti General
Troubleshooting Procedures). See: Diagrams/Diagnostic Aids
^
Refer to System Diagnosis. See: Flow of Diagnosis