buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Sensors and Switches - Instrument Panel > < Compressor High-Pressure and Low-Pressure Cut Off Switch
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair
Pressure Cycling Switch

1.

Disconnect negative battery cable. Under normal conditions, it is not necessary to discharge system refrigerant during this procedure, as 
switch unit fitting is supplied with a Schrader valve.

2.

Disconnect switch harness connection. Unscrew unit from accumulator.

3.

When installing new switch unit, install new oiled O-ring and torque switch to 7.5 ft. lbs. Be careful not to over tighten switch.

4.

Reconnect harness and battery cable. 

Sensors and Switches - Instrument Panel > < Compressor High-Pressure and Low-Pressure Cut Off Switch