buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

All Other Service Bulletins for Spark Plug Wire: > < All Other Service Bulletins for Spark Plug Wire:|531212A|Page 837
Page 1
background image

Evaporator Core: All Technical Service Bulletins
A/C - White Powder Coming From HVAC Vents When ON

Bulletin: 93-I-12
Date:  July, 1993
Ref.No.: 93
Corp.Ref.No.: 331220

MODELS:
1993 ROADMASTERS

SUBJECT:
White Powder Coming From A/C Vents During Operation (Replace Evaporator)

CONDITION:
White dust or flakes can be emitted from the HVAC vents during operation.

CAUSE:
The dusting or flaking is caused by silicate coating flaking from the evaporator core. The flaking material is a non-crystalline silicone dioxide which
represents no health or toxicity risk. This condition is initiated by usage of the A/C system including wetting and drying cycles of the evaporator core.
The duration and amount of dust is variable and will disappear with time and usage. With regular A/C usage, some vehicles have stopped flaking within
2 or 3 days, although other vehicles may persist for several weeks.

CORRECTION:
Replace the evaporator core with P/N 52458278. Replacement evaporator cores are not coated with silicate coating.

Follow procedure in Service Manual, Section 1B1. For evaporator removal, it may be helpful to remove the evaporator studs. This can be accomplished
by using a female E7 torx bit socket or by installing double nuts on studs.

Note: 

Water can leak onto carpeting during this procedure, it is recommended that a mat be placed on passenger side floor before removing lower 
evaporator case.

Module water core filter must be removed from evaporator core (by removing push pins) and transferred to new core. Before installing, thoroughly rinse
filter with water and be certain that there is no remaining silicate material. Make sure filter is in the same orientation as original filter.

In addition to normal service procedure, the evaporator case and duct system should be thoroughly cleaned. Thoroughly vacuum or blow out inside of
evaporator case, heater outlet and any accessible ducts. Wipe out upper and lower evaporator case interior with a damp cloth before installing
evaporator.

After replacement of the evaporator core, the HVAC system should be cycled through all modes on high blower speed to dislodge any remaining
particles. Thoroughly vacuum any surface of the vehicle where dust may have accumulated. Cleaning of the ducts and case is particularly critical in
avoiding customer comebacks.

Parts are currently available from GMSPO.

WARRANTY INFORMATION:
Labor Operation: T3361

1.1 Hrs.

Add to discharge & charge A/C system

.7 Hrs.

All Other Service Bulletins for Spark Plug Wire: > < All Other Service Bulletins for Spark Plug Wire:|531212A|Page 837