Skyhawk L4-112 1.8L Turbo VIN J FI (1984)
Fig. 17 Round wiper motor current draw specifications
INTERMITTENT OPERATION
1.
Check solder connections at wiper terminal board.
2.
Connect wiper to operate in LO speed, Fig. 14. Connect ammeter (range 0---30 amps) in feed wire circuit to wiper and observe current draw.
Allow motor to run until it becomes hot; see Specification Chart, Fig. 17.
a. If current draw is normal and wiper cycles on and off, a weak circuit breaker is indicated. Replace brush plate assembly.
b. If current draw exceeds specification, proceed to Steps 3, 4 and 5.
3.
Adjust armature end play as required armature on growler for shorted or grounded condition.