Skylark L4-144 2.4L DOHC VIN T SFI (1997)
A/C Signal: Testing and Inspection
A/C Refrigerant Pressure Sensor
A scan tool displays A/C refrigerant pressure in psi. The sensor's range and corresponding display should be in the range of 0 to 450 psi. A poor ground
at the sensor will result in a fixed high pressure value on the scan tool display. A sensor or circuit problem should set DTC P0530.