Skylark L4-144 2.4L DOHC VIN T SFI (1997)
Camshaft Position Sensor: Diagnostic Aids
Testing For Voltage Drop
Voltage Drop Test
This test checks for voltage being lost along a wire, or through a connection or switch.
1. Connect the positive lead of a Digital Voltmeter (DVM) to the end of the wire (or to one side of the connection or switch) which is closer to the
Battery.
2. Connect the negative lead to the other end of the wire (or the other side of the connection or switch).
3. Operate the circuit.
4. The DVM will show the difference in voltage between the two points.