buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Lamps and Indicators - A/T > < Hydraulic Thermo Valve, A/T|Service and Repair
Page 2
background image

^

Thermo element.

^

Plate.

INSTALL OR CONNECT

1. Set middle thermo pin height with J 3409-A.
2. Element plate.
3. Pin and washer assemblies using J 34094-A to set the height of both washers. First, set the pin that is furthest from the accumulators. Then set the

other pin. This will ensure that both pins will be set correctly.

4. Thermo element between the two pins without bending the element too much. "V" in Thermo element must contact the element plate.
5. Filter, new gasket, oil pan. 
6. Negative battery cable.

Adjust

^

Oil level.

Lamps and Indicators - A/T > < Hydraulic Thermo Valve, A/T|Service and Repair