buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Recall - Power Window Module Replacement|Page 207 > < Heated Glass Element Relay|Locations
Page 1
background image

Power Window Control Module: Recalls
Recall - Power Window Module Replacement

Model Year:
1991

Bulletin No.: 
91-C-5

File in Group:
8

Number:
53

Date:
April '92

SUBJECT:
POWER WINDOW FAILURES

MODELS AFFECTED:
CERTAIN 1991 BUICK SKYLARK EQUIPPED WITH POWER WINDOWS (RPO A31)

The National Traffic and Motor Vehicle Safety Act, as amended, provides that each vehicle which is subject to a recall campaign of this type must be
adequately repaired within a reasonable time after the owner has tendered it for repair. A failure to repair within sixty (60) days after tender of a vehicle
is prima facie evidence of failure to repair within a reasonable time.

If the condition is not adequately repaired within a reasonable time, the owner may be entitled to an identical or reasonably equivalent vehicle at no
charge or to a refund of the purchase price less a reasonable allowance for depreciation.

To avoid having to provide these burdensome solutions, every effort must be made to promptly schedule an appointment with each owner and to repair
their vehicle as soon as possible. As you will see in reading the attached copy of the letter that is being sent to owners, the owners are being instructed to
contact the Buick Customer Assistance Center if their dealer does not remedy the condition within five (5) days of the mutually agreed upon service date.
If the condition is not remedied within a reasonable time, they are instructed on how to contact the National Highway Traffic Safety Administration.

DEFECT INVOLVED

General Motors has determined that a defect which relates to motor vehicle safety exists in certain 1991 Buick Skylark models equipped with power
windows (RPO A31). These vehicles may exhibit a condition in which moisture enters the express-down electronic control module and creates
undesirable continuity. This may result in window operation without operator input and could cause the window to remain down. The module may
eventually fail by overheating, which could result in a fire in the door panel area.

Recall - Power Window Module Replacement|Page 207 > < Heated Glass Element Relay|Locations