REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
CAUTION: Refer to Battery Disconnect Caution In Service Precautions.
2. Remove the valve rocker covers. Refer to Valve Rocker Arm Cover Replacement.
3. Remove the rocker arm bolts.
IMPORTANT: Keep the components separated so they may be installed in the same location.
4. Remove the rocker arm pivot balls.
5. Remove the rocker arms.
6. Remove the pushrods.