Skylark V6-3100 3.1L VIN M SFI (1996)
Canister Purge Solenoid: Service and Repair
EVAP Canister Purge Valve And Vacuum Switch
REMOVE OR DISCONNECT
1. Remove the negative battery cable.
2. Note the position of the hoses for installation.
3. Remove the electrical connector and hoses from solenoid.
4. Release the lock tab on the solenoid mounting bracket.
5. Remove the solenoid.
INSTALL OR CONNECT
1. Install the solenoid to solenoid mounting bracket.
2. Install the electrical connector and hoses to solenoid.
3. Connect the negative batterv cable.