Terraza AWD V6-3.5L VIN L (2006)
Blower Motor: Service and Repair
Blower Motor Replacement - Auxiliary (With RPO Code E59)
BLOWER MOTOR REPLACEMENT - AUXILIARY (WITH RPO CODE E59)
REMOVAL PROCEDURE
1. Remove the left lower quarter trim panel.
2. Disconnect the auxiliary blower motor electrical connector.
3. Disconnect the auxiliary blower motor resistor electrical connector.
4. Remove the lower auxiliary air distribution duct bolts and retainers.
5. Remove the lower auxiliary air distribution duct.
6. Remove the auxiliary blower motor housing screws.
IMPORTANT: The auxiliary blower motor must be removed with the blower motor housing.
7. Lift the auxiliary blower motor housing and remove from the HVAC module assembly.