chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

With Air Conditioning|Page 5440 > < Diagram Information and Instructions|Page 5437
Page 1
background image

Blower Motor: Description and Operation
With Air Conditioning

Front

CIRCUIT DESCRIPTION

In all blower speeds except HI, voltage to the Blower Motor is supplied by the HTR A/C Fuse. In HI blower speed, the Blower Relay is energized and
voltage is supplied to the Blower Motor by the GRA (2) fusible link and RED (2) wire.

The Blower Motor operates whenever the A/C Heater Select Control is in MAX A/C, NORM A/C, BI-LEVEL, BLEND or DEFROST. Voltage
through the A/C Heater Select Control is available to the Blower resistors through the YEL (51) wire. The current then flows through all three
resistors and the normally closed contacts of the HI Blower Relay to the Blower Motor and the Blower Motor runs at LOW speed. With the A/C
Heater Select Control in VENT or HEAT no voltage is available to the Blower Motor.

With the Blower Switch in MED/LO, current flows from the HTR A/C Fuse through the Blower Switch, the TAN (63) wire to the Blower Resistors.
Current then flows through two of the resistors and the normally closed contacts of the HI Blower Relay to the Blower Motor. The Blower Motor then
runs at MED/LO speed.

With the Blower Switch in MED/HI, the blower operates the same as in LO Speed, except that the current is directed to the Blower Resistors through
the LT BLU (72) wire and passes through only one resistor and the Blower Motor runs at MED/HI speed.

With the Blower Switch in HI, current bypasses the Blower Resistors and flows to the HI Blower Relay. This current energizes the relay and closes the
normally open contacts of the relay. This allows battery voltage to be applied directly to the Blower Motor causing it to run at HI speed.

Rear

CIRCUIT DESCRIPTION

The Auxiliary A/C Blower Motor delivers air to the interior of the vehicle. Its speed is controlled by the Blower Switch and the Blower Resistors.
When the Ignition Switch is in RUN, battery voltage is supplied to the Blower Switch. With the Blower Switch in LO, voltage is supplied across both
Blower Resistors and the Blower Motor. The Blower Motor runs at its slowest speed. With the Blower Switch in MED, one of the Blower Resistors is
bypassed and the Blower Motor runs faster. When the Blower Switch is set to HI, battery voltage is supplied directly to the Blower Motor and the
Blower Motor runs at its fastest speed.

With Air Conditioning|Page 5440 > < Diagram Information and Instructions|Page 5437