chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Expansion Block/Orifice Tube|Locations|Page 5675 > < Expansion Block/Orifice Tube|Locations|Page 5673
Page 2
background image

Front Plumbing Component View

REMOVE OR DISCONNECT

1. Discharge and recover refrigerant from the system.
2. Evaporator tube from evaporator.
3. O-ring.
4. Expansion (orifice) tube from evaporator.

INSTALL OR CONNECT

1. Expansion (orifice) tube into evaporator.
2. New O-ring.

^

Coat O-ring with 525 viscosity refrigerant oil.

3. Evaporator tube to evaporator.

Expansion Block/Orifice Tube|Locations|Page 5675 > < Expansion Block/Orifice Tube|Locations|Page 5673