Avalanche 1500 2WD V8-5.3L VIN Z Flex Fuel (2005)
REMOVAL PROCEDURE
1. Remove the air distribution duct.
2. Disconnect the electrical connection from the recirculation actuator (1).
3. Remove the recirculation actuator retaining screws.
4. Remove the recirculation actuator.
INSTALLATION PROCEDURE
1. Install the recirculation actuator.
2. Install the recirculation actuator retaining screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 1.6 N.m (14 lb in).
3. Connect the electrical connector to the recirculation actuator (1).
4. Install the air distribution duct.