chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Starting System > < Diagram Information and Instructions|Page 9324
Page 2
background image

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the generator mounting bolts.

Tighten
Tighten the bolts to 50 N.m (37 lb ft).

3. Connect the electrical connections to the generator.

Tighten
Tighten the B+ nut to 18 N.m (13 lb ft).

4. Install the accessory drive belt. 
5. Connect the negative battery cable.

Tighten
Tighten to bolt to 17 N.m (13 lb ft).

Starting System > < Diagram Information and Instructions|Page 9324