16. Attach J 43485 to J 35555 or equivalent.
17. Place J 43485 on the pump reservoir filler neck.
18. Apply a vacuum of 20 Hg maximum.
19. Wait 5 minutes.
20. Verify the fluid level.
21. Reinstall the pump reservoir cap.
SPECIAL CONDITIONS PROCEDURE
-
Tools Required
-
J 35555 Mity Vac
-
J 43485 Power Steering Bleed Adapter
1. If the vacuum continues to drop, remove the pressure and return hose from the pump.
2. Install the plugs (1) (2) supplied with J 43485 into the pressure and return port.