chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Air Flow Meter/Sensor > < Accelerator Pedal Position Sensor|Diagrams|Page 2204
Page 2
background image

1. Install the APP assembly.

NOTE:  Refer to the Fastener Notice in Service Precautions.

2. Install the APP assembly bolts.

Tighten
Tighten the bolts to 20 N.m (15 lb ft).

3. Reposition the carpet.

4. Connect the APP sensor electrical connector.
5. Install the CPA retainer.
6. Connect a scan tool in order to check for the proper throttle-opening and throttle-closing range.
7. Verify that the vehicle meets the following conditions:

^

The vehicle is not in a reduced engine power mode.

^

The ignition is ON.

^

The engine is OFF.

8. Operate the accelerator pedal and monitor the throttle angles. The accelerator pedal should operate freely, without binding, between a closed

throttle, and a wide open throttle (WOT).

Air Flow Meter/Sensor > < Accelerator Pedal Position Sensor|Diagrams|Page 2204