CAUTION: Do not use a meter with an impedance of less than 10 Meg ohms.

1. Insert the positive probe into terminal H (circuit 903) and the negative probe into terminal 4 (circuit 904). Set the control to HEATER, pause

briefly.

2. SET THE CONTROL TO DEFROST. The meter should read -7.0 to -7.5 volts. This voltage will only last about 5 seconds after the control is

moved, after that it will return to 0 volts.

3. SET THE CONTROL TO HEATER. The meter should read +7.0 to + 7.5 volts for 5 seconds.
4. SET THE CONTROL TO UPPER AIR. The meter should read +7.0 to +7.5 volts for 5 seconds.

CAUTION: The controller may not deliver the correct voltages to the mode door actuator If the feedback circuit is faulty. Refer to "Mode Door
Feedback Circuit Test"

Mode Door Feedback Circuit

Symptom Related Diagnostic Procedures|Page 7270 > < Symptom Related Diagnostic Procedures|Page 7268