chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Mechanical Specifications|Page 10446 > < Mechanical Specifications
Page 1
background image

Accumulator HVAC: Capacity Specifications

The Harrison HT-6 compressor system used on all models requires polyalkaline glycol (PAG) refrigerant oil in the quantities listed below:

-

Without Aux. A/C - 240 ml (8 fl oz) 

-

With Aux. A/C - 330 ml (11 fl oz)

New oil quantities must be added to the system during component replacement and conditions stated as follows:

-

With no signs of excessive oil leakage, add:

A. All Compressors (drain and measure the oil)

-

If less than 30 ml (1 fl oz) is drained-add 60 ml (2 fl oz) to the new compressor.

-

If more than 30 ml (1 fl oz) is drained-add same amount that was drained to the new compressor.

B. Accumulator-Add 105 ml (3.5 fl oz) of new oil to the replacement accumulator to compensate for oil retained by original accumulator

desiccant and bag assemblies. The accumulator should only be replaced if leaking due to a perforation, damaged O-ring seal seat, or
damaged threads.

C. Evaporator-Add 90 ml (3 fl oz) of new refrigerant oil.

D. Condenser-Add 30 ml (1 fl oz) of new refrigerant oil.

Mechanical Specifications|Page 10446 > < Mechanical Specifications