Refrigerant Pressure Sensor / Switch: Service and Repair
Cut-Off Switch Service

Compressor Pressure Switch

Remove or Disconnect 

1. Negative battery cable. 
2. Electrical connectors, as necessary.
3. Compressor pressure switch.
4. O-Ring seal.

Install or Connect 

1. New O-ring seal.

-

Coat O-ring seal with 525 viscosity refrigerant oil.

2. Compressor pressure switch. Tighten Compressor pressure switch to 6 Nm (53 lb. in.).
3. Electrical connectors, as necessary.
4. Negative battery cable.