6. Install the turbocharger bypass valve and sealing washer to the water outlet tube.

^

Tighten the turbocharger bypass valve to 60 Nm (44 ft. lbs.).

7. Connect the turbocharger coolant hose to the turbocharger bypass valve.

8. Install the bolt and wiring harness bracket to the thermostat housing.

^

Tighten the wiring harness bracket bolt to 8 Nm (71 inch lbs.).