C 3500 HD Truck 2WD V8-6.5L DSL Turbo VIN F (2001)
1. Install the surge tank.
Notice: Refer to Fastener Notice in Service Precautions.
2. Install the surge tank bolts.
Tighten the surge tank bolts to 9 Nm (80 inch lbs.).
3. Install the surge tank outlet hose to the surge tank.
4. Position the surge tank outlet hose clamp.
5. Install the surge tank inlet hose to the surge tank.
6. Position the surge tank inlet hose clamp.
7. Connect the low coolant probe electrical connector.
8. Fill the cooling system.