chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Compressor Hose Assembly Replacement|Page 8113 > < Compressor Hose Assembly Replacement
Page 2
background image

1. Coat the new O-ring seal with 525 viscosity refrigerant oil.
2. Install the new O-ring seal to the condenser hose.

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Connect the compressor hose assembly to the condenser.

Tighten
Tighten the hose assembly to 20 N.m (15 lb ft).

4. Coat the new dual O-ring seals with 525 viscosity refrigerant oil.
5. Install the new dual O-ring seals to the accumulator hose.
6. Connect the hose assembly to the accumulator.

Tighten
Tighten the hose assembly to 25 N.m (18 lb ft).

7. Install the sealing washers.
8. Connect the compressor hose assembly to the top of the compressor.
9. Install the compressor hose bolt to the A/C compressor.

Tighten
Tighten the bolt to 34 N.m (25 lb ft).

10. Install the grille.
11. Evacuate and recharge the refrigerant system. Refer to Refrigerant Recovery and Recharging.
12. Leak test the fittings of the component using the J 39400-A.