chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < A/C - Loss of Mode or Temperature Control|Page 8184
Page 1
background image

Blower Motor Switch: Service and Repair

BLOWER SWITCH REPLACEMENT

REMOVAL PROCEDURE

1. Remove the IP cluster bezel.
2. Remove the control assembly by releasing the snap-fit retainers using a small screwdriver.
3. Disconnect the electrical connection.
4. Disconnect the cables from the control assembly by releasing the retainers, if equipped.
5. Remove the blower switch rotary knob and the retaining clip from the shaft of the blower switch.
6. Remove the blower switch.

INSTALLATION PROCEDURE

1. Install the blower switch.

1.1. Hold the blower switch in position.
1.2. Install the retaining clip.
1.3. Install the blower switch rotary knob

2. Connect the cables to the control assembly.
3. Connect the electrical connection.
4. Snap the control assembly into the instrument panel.
5. Install the instrument panel trim plate.

Refrigerant Pressure Sensor / Switch, HVAC > < A/C - Loss of Mode or Temperature Control|Page 8184