C 3500 HD Truck 2WD V8-8.1L VIN G (2002)
1. Install the thermostat (3) to the water crossover.
2. Install the water outlet (1).
Notice: Refer to Fastener Notice in Service Precautions.
3. Install the water outlet bolts.
Tighten the water outlet bolts to 30 Nm (22 ft. lbs.).
4. Install the inlet hose (2) to the water outlet.
5. Position the inlet hose clamp (1) at the water outlet.
6. Add coolant as necessary.