Accumulator HVAC: Service and Repair

ACCUMULATOR REPLACEMENT

TOOLS REQUIRED

-

J 38042 Dual O-Ring Tube Separator

-

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Disconnect the electrical connector from the low pressure switch.
3. Remove the low pressure cycling switch from the accumulator.
4. Remove the compressor hose assembly nut from the accumulator using the J 38042.
5. Remove the accumulator nut from the evaporator using the J 38042.

IMPORTANT:  Cap or plug all of the open connections.

6. Remove the O-ring seals from the accumulator.
7. Remove the accumulator bracket screw.
8. Remove the accumulator.
9. Remove the upper and the lower accumulator insulators.

INSTALLATION PROCEDURE

Accumulator HVAC|Locations|Page 9236 > < Accumulator HVAC|Locations